Thu, 24 May, 2012, 10:13 AM EDT - Canadian Markets close in 5 hrs 47 mins

Rock Tech Samples 1.37% Lithium Oxide over 20.96 metres at Georgia Lake

Vancouver, British Columbia, Canada, January 18, 2011 - Rock Tech Lithium Inc. (TSX-Venture: RCK; Frankfurt: RJIA; Pink Sheets: RCKTF) (the "Company" or "Rock Tech") is pleased to announce assay results from the second phase ("Phase 2") of its exploration program at its Georgia Lake lithium project. The program, consisting of 4,608 metres of diamond drilling over 18 drill holes in addition to 16 channel samples, tested pegmatite dykes located on the Nama Creek, Conway and Newkirk claim blocks.

The objective of Phase 2 of the exploration program is to expand the resource announced on October 26, 2011, of 2.36 million tonnes of 1.17% lithium oxide ("Li2O") indicated and 4.36 million tonnes of 1.08% Li2O inferred.

Highlights of the drill results are as follows:

-1.09% Li2O over 8.33 metres and 0.94% Li2O over 3.0 metres in drill hole L60-11-03;

-1.12% Li2O over 7.0 metres and 1.12% Li2O over 2.0 metres in drill hole L60-11-04; and

-2.11% Li2O over 1.0 metre and 0.79% Li2O over 2.0 metres in drill hole L60-11-05.

Highlights of the channel sampling results are as follows:

-1.50% Li2O over 8.03 metres in Channel L60-11-C01

-1.45% Li2O over 12.99 metres in Channel L60-11-C04

-1.37% Li2O over 20.96 metres in Channel L60-11-C09

-1.45% Li2O over 14.08 metres in Channel L60-11-C06

-1.45% Li2O over 19.51 metres in Channel L60-11-C08

-1.04% Li2O over 11.01 metres in Channel L60-11-C10

Anomalous values of rare metals including rubidium, beryllium, cesium, niobium and tantalum were also encountered. Detailed assay results can be found in the tables below:

Table 1: Drill Hole Assay Results





 -------------------------------------------------------------------

 |Drill    |Area   |Depth |Depth To|Length|Li2O|Be |Rb |Cs |Nb |Ta |

 |Hole     |       |From  |        |      |    |   |   |   |   |   |

 |ID       |       |      |        |      |    |   |   |   |   |   |

 |         |-------------------------------------------------------|

 |         |       |Metres|Metres  |Metres|%   |ppm|ppm|ppm|ppm|ppm|

 |-----------------------------------------------------------------|

 |L60-11-03|Line 60|53.00 |61.33   |8.33  |1.09|123|631|36 |20 |25 |

 |         |-------------------------------------------------------|

 |         |       |64.33 |67.33   |3.00  |0.94|121|701|46 |27 |41 |

 |         |-------------------------------------------------------|

 |         |       |70.90 |71.90   |1.00  |0.73|150|775|43 |37 |87 |

 |-----------------------------------------------------------------|

 |L60-11-04|Line 60|80.00 |87.00   |7.00  |1.12|114|782|51 |25 |36 |

 |         |-------------------------------------------------------|

 |         |       |89.00 |91.00   |2.00  |1.12|110|628|41 |13 |14 |

 |         |-------------------------------------------------------|

 |         |       |170.80|171.35  |0.55  |0.95|107|465|33 |22 |23 |

 |-----------------------------------------------------------------|

 |L60-11-05|Line 60|18.63 |19.63   |1.00  |2.11|173|903|58 |31 |35 |

 |         |-------------------------------------------------------|

 |         |       |95.92 |97.92   |2.00  |0.79|147|842|57 |28 |29 |

 |         |-------|      |

 |         |       |      |

 -------------------------------------------------------------------

Li2O = lithium oxide; Be = beryllium; Cs = cesium; Nb = niobium; Ta = tantalum; Rb = rubidium

Analytical methods: Li2O calculated from Li ppm (parts per million) by FUSNA202; RB, Cs, Nb by FUSMS, Be by FUSICP

The true thickness of the drill intersection may be less than the reported intervals

Table 2: Channel Sample Assay Results





 ---------------------------------------------------------------------

 |Channel ID |Area   |Depth |Depth To|Length|Li2O|Be |Rb  |Cs |Nb |Ta|

 |           |       |From  |        |      |    |   |    |   |   |  |

 |           |----------------------------------------------------|

 |           |Metres |Metres|Metres  |%     |ppm |ppm|ppm |ppm|ppm|

 |-------------------------------------------------------------------|

 |L60-11-C01 |Line 60|5.66  |13.69   |8.03  |1.50|180|831 |47 |25 |38|

 |-------------------------------------------------------------------|

 |L60-11-C02 |Line 60|1.46  |5.51    |4.05  |1.22|191|1097|55 |24 |35|

 |-------------------------------------------------------------------|

 |L60-11-C03 |Line 60|1.61  |7.44    |5.83  |1.53|186|697 |48 |24 |31|

 |-------------------------------------------------------------------|

 |L60-11-C04 |Line 60|1.95  |14.94   |12.99 |1.45|181|842 |58 |22 |30|

 |-------------------------------------------------------------------|

 |L60-11-C05A|Line 60|1.01  |6.09    |5.08  |1.24|125|778 |51 |21 |25|

 |-------------------------------------------------------------------|

 |L60-11-C05B|Line 60|4.29  |11.22   |6.93  |1.36|168|863 |68 |27 |36|

 |-------------------------------------------------------------------|

 |L60-11-C05C|Line 60|2.07  |2.86    |0.79  |1.03|170|964 |60 |33 |51|

 |-------------------------------------------------------------------|

 |L60-11-C05D|Line 60|1.01  |2.44    |1.43  |1.28|167|825 |63 |52 |85|

 |-------------------------------------------------------------------|

 |L60-11-C06 |Line 60|1.99  |3.00    |1.01  |1.08|70 |725 |42 |19 |27|

 |-------------------------------------------------------------------|

 |L60-11-C06 |Line 60|4.97  |19.05   |14.08 |1.45|160|831 |58 |20 |26|

 |-------------------------------------------------------------------|

 |L60-11-C07A|Line 60|3.16  |4.05    |0.87  |1.10|66 |536 |29 |7  |4 |

 |-------------------------------------------------------------------|

 |L60-11-C07A|Line 60|6.05  |16.54   |10.49 |1.50|164|989 |60 |20 |27|

 |-------------------------------------------------------------------|

 |L60-11-C07A|Line 60|18.54 |20.39   |1.85  |0.97|84 |845 |52 |15 |17|

 |-------------------------------------------------------------------|

 |L60-11-C07B|Line 60|0.73  |1.53    |0.80  |1.18|190|718 |62 |56 |74|

 |-------------------------------------------------------------------|

 |L60-11-C08 |Line 60|1.87  |2.77    |0.90  |1.40|69 |724 |48 |12 |16|

 |-------------------------------------------------------------------|

 |L60-11-C08 |Line 60|3.67  |23.18   |19.51 |1.45|153|852 |58 |17 |30|

 |-------------------------------------------------------------------|

 |L60-11-C09 |Line 60|3.01  |23.97   |20.96 |1.37|145|853 |58 |25 |33|

 |-------------------------------------------------------------------|

 |L60-11-C10 |Line 60|1.76  |12.77   |11.01 |1.04|123|1028|58 |23 |33|

 |-------------------------------------------------------------------|

 |L60-11-C10 |Line 60|13.79 |19.67   |5.88  |1.09|140|783 |53 |26 |32|

 |-------------------------------------------------------------------|

 |CW-11-C01  |Conway |2.39  |5.41    |3.02  |1.27|160|1042|78 |34 |30|

 |-------------------------------------------------------------------|

 |CW-11-C01  |Conway |6.33  |9.24    |2.91  |0.93|140|1047|102|32 |26|

 |-------------------------------------------------------------------|

 |CW-11-C03A |Conway |0.00  |5.14    |5.14  |1.01|145|864 |63 |30 |24|

 |-------------------------------------------------------------------|

 |CW-11-C03B |Conway |0.00  |4.90    |4.90  |1.43|157|796 |60 |17 |16|

 |-------------------------------------------------------------------|

 |NK-11-C01  |Newkirk|0.00  |3.11    |3.11  |1.74|167|992 |57 |87 |65|

 ---------------------------------------------------------------------

No significant Li2O in L60-11-C04B, L60-11-C07C, CW-11-C02, and NK11-C02

Li2O = lithium oxide; Be = beryllium; Cs = cesium; Nb = niobium; Ta = tantalum; Rb = rubidium

Analytical methods: Li2O calculated from Li ppm (parts per million) by FUSNA202; RB, Cs, Nb by FUSMS, Be by FUSICP

Company President and CEO, Eunho Lee, commented, "The channel sample results at the Line 60 pegmatite dyke at Nama Creek has far exceeded our expectations in terms of both lithium oxide grades and widths. This data, along with the recently received and pending assay results, will be incorporated into a three dimensional model and be included in an updated NI 43-101-compliant resource estimate."

In other news, Rock Tech has retained the services of Sean Davis as an employee to manage the Company's investor and public relations functions.

Quality Assurance / Quality Control

Samples were prepared by Actlabs' preparation lab in Geraldton, Ontario, and then shipped to Actlabs' analytical lab in Ancaster, Ontario, for analysis. Actlabs is accredited by ISO 17025. The samples were digested using lithium metaborate/tetraborate fusion and analyzed for the major elements by ICP and trace elements by ICP/MS. The samples were digested by sodium peroxide fusion and analyzed for lithium using ICP/OES.

Caracle Creek International Consulting ("CCIC") inserted standards and blanks into the sample stream in regular intervals with every tenth sample being a low-grade lithium standard, a high-grade lithium standard or a blank. Additionally, one in every twenty samples was a core duplicate. The external standards and blanks passed QC review for all drill holes in this press release. Actlabs also analyzed pulp and preparation duplicates and method blanks as part of their QA/QC program.

The technical information contained in this news release has been reviewed by Afzaal Pirzada, P.Geo., Vice President, Exploration of the Company and a Qualified Person as defined in NI 43-101.

On behalf of the Board of Directors,

"Eunho Lee"

Eunho Lee

Director, President and CEO

For more information, please contact:

Sean Davis

Investor and Public Relations

Rock Tech Lithium Inc.

789 West Pender Street, Suite 1205

Vancouver, B.C., V6C 1H2

Telephone: (604) 688-1140, ext. 227

Facsimile: (604) 688-1173

Email: sdavis@rocktechlithium.com

Disclaimer and Cautionary Statement Regarding Forward-Looking Information

Neither the TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in the policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of this press release. This news release shall not constitute an offer to sell or the solicitation of an offer to buy securities in any jurisdiction.

All statements, trend analysis and other information contained in this press release relative to markets about anticipated future events or results constitute forward-looking statements. Forward-looking statements are often, but not always, identified by the use of words such as "seek", "anticipate", "believe", "plan", "estimate", "expect" and "intend" and statements that an event or result "may", "will", "should", "could" or "might" occur or be achieved and other similar expressions. Forward-looking statements are subject to business and economic risks and uncertainties and other factors that could cause actual results of operations to differ materially from those contained in the forward-looking statements. Forward-looking statements are based on estimates and opinions of management at the date the statements are made. The Company does not undertake any obligation to update forward-looking statements even if circumstances or management's estimates or opinions should change. Investors should not place undue reliance on forward-looking statements.

Market Data

  • Currencies
    Currencies
    NamePriceChange% Chg
    0.9748-0.00-0.12%
    CADUSD=X
    0.7749-0.00-0.06%
    CADEUR=X
    0.6212-0.00-0.12%
    CADGBP=X
  • Commodities
    Commodities
    NamePriceChange% Chg
    97.410004-1.41-1.43%
    CLZ11.NYM
    3.50-0.09-2.51%
    NGX11.NYM
    1,652.00-70.70-4.10%
    GCV11.CMX
    35.3150.22+0.63%
    SIV11.CMX
  • Popular Stocks
    Popular Stocks
    NamePriceChange% Chg
    571.200.64+0.11%
    AAPL
    10.75-0.34-3.07%
    RIMM
    606.24-3.22-0.53%
    GOOG
    10.5180.11+1.04%
    F
    19.220.04+0.21%
    GE
    22.02-0.07-0.32%
    PFE
    2.730.00+0.00%
    NOK
 

There are no comments yet